Electric air damper drives Article SR-15D/230-S

Electric air damper actuator SR-15D/230-S with spring return, 230V

Electric driveSR-15D/230-S with spring returnto automatically return the damper to its original position when the power is turned off (fail-safe). Torque15 Nm,…

Cost of equipment By calculation

Calculated after specifying the performance, execution and composition of the supply.

Contact on WhatsApp

Send us the parameters or technical specifications - the engineer will specify the equipment for your facility.

Model
SR-15D/230-S
Torque
15 Nm
Supply voltage
230 V
Execution
with spring return (fail-safe)
Model preselection Product card parameters help compare the product range, but do not replace the datasheet for the selected configuration. The scope, specifications and suitability are confirmed after we review the TOR.

Engineering solution

What this equipment is designed to solve

Electric driveSR-15D/230-S with spring return to automatically return the damper to its original position when the power is turned off (fail-safe). Torque15 Nm, power supply 230 V.

It is used where it is important to move the damper to the position specified by the design when removing power: external air intakes, protection of air heaters, units where spring return is required; Use in security systems is permitted only if the required certificates are available.

Application

Suitable applications

  • Air valves and dampers
  • General ventilation systems
  • Air handling units
  • Automation of engineering systems

Preliminary parameters

Characteristics

Values are not contractual until the selected configuration is confirmed in the technical proposal and data sheet.

ModelSR-15D/230-S
Torque15 Nm
Supply voltage230 V
Executionwith spring return (fail-safe)
Management2-position
Purposedampers requiring emergency return

There is no passport for a specific actuator or valve in the current site kit; torque, power supply, control signal, dimensions and compatibility are confirmed according to the delivery model.

For procurement and approval

Documentation

The set of documentation is specified for the selected design.

Request the available datasheet, drawing or certificates together with the quotation.

Frequently Asked Questions

In the event of a power failure, the spring automatically returns the damper to a safe position – protecting the ventilation and equipment during a power outage.

Do you need to select equipment for your project?

Send the terms of reference, questionnaire or basic parameters. We will prepare a complete set and a commercial offer.

+7 (771) 006-77-11 WhatsApp ↗