Order design and installation of ventilation for chemical laboratories
ABL Engineering Group carries out a full cycle of work – from technical calculation of parameters and design of the ventilation system to the supply of equipment, installation of air ducts and commissioning of automation. Over the years, the company has completed 40+ industrial and laboratory facilities, gaining expertise in projects with increased requirements for air safety.
Chemical laboratories are facilities with a high concentration of harmful substances in the work area. Supply and exhaust systems here are required not only to provide air exchange, but also to control the air supply speed in each zone, maintain a vacuum in fume hoods, ensure purification of the exhaust flow through specialized filters and exclude the recirculation of contaminated air into work areas. Our engineers calculate the air exchange rate, select fans with the required pressure and performance characteristics, and design air duct routes taking into account the laboratory layout and the location of fume hoods.
Our own production in Temirtau – two workshops with a total area of more than 1,000 m² and a CNC machine park – allows us to produce non-standard elements of the ventilation system in strict accordance with the design documentation. This eliminates dependence on third-party suppliers and reduces installation time.
What is included in the comprehensive service:
- Technical calculation and design of the ventilation system taking into account SNiP and SanPiN standards for chemical laboratories
- Selection and supply of fans, air ducts, air purification filters and fume hoods
- Installation of supply and exhaust units and air duct routing using our own installation teams
- Installation and configuration of automation: gas sensors, air supply speed controllers, emergency switching systems
- Integration of heat recovery where it is technically justified and does not create a risk of recirculation of harmful substances
- Commissioning, testing and transfer of as-built documentation
- Maintenance of installed systems
Our own installation teams work throughout Kazakhstan: Almaty, Astana, Temirtau, Shymkent, Aktobe and other regions. The design department is headed byKorzhuk Lyubov Ivanovna(Head of the Technical Department), production and supply –Korzhuk Alexey Alexandrovich. Technical support of projects is carried out by Technical Department engineers, includingSemenok Alexander Alexandrovich. Commercial issues and agreement of conditions are in the area of responsibilityKhasanov Ildar Ildarovich(Sales and Project Management Department).
Important: ABL Engineering Group works exclusively with B2B customers – industrial enterprises, scientific organizations, medical institutions and commercial facilities of any size. The company does not carry out ventilation projects for residential premises and private facilities.
Ensuring the safety and compliance of chemical laboratory ventilation requirements
A chemical laboratory is a high-risk facility, where control of the composition of air masses directly determines the safety of personnel. Working with toxic substances, aggressive vapors and harmful gases creates stringent requirements for ventilation systems: they must not only provide air exchange, but also keep the concentrations of hazardous and harmful substances below the maximum permissible levels established by current regulatory documents.
ABL Engineering Group designs and installs ventilation systems for chemical laboratories in strict accordance with relevant standards –SNiP RK 4.02-42, SanPiN and industry regulations on labor protection. Each design solution is tested for compliance with regulatory requirements at the stage of calculating parameters: air exchange rate, rate of removal of contaminated air flows, vacuum level in fume hoods – all this is included in the technical documentation before installation begins.
Key principle: Compliance with regulations is not a formality, but an engineering task. Insufficient exhaust or incorrectly designed air ducts create a real risk of leakage of toxic gases and accumulation of harmful substances to dangerous concentrations.
Our specialists – including the head of the technical department Korzhuk Lyubov Ivanovna and the Technical Department engineer Semenok Alexander Aleksandrovich – provide full documentary support: from initial data to as-built documentation confirming the compliance of the installed system with all regulatory requirements.
- Control of maximum permissible concentrations (MPC)— calculations are carried out for each class of harmful and toxic substances used in the laboratory.
- Compliance with air flow regulations— the rate of air supply and removal complies with the requirements of SNiP and SanPiN for laboratory premises.
- Reduce the risk of hazardous substances leaking— systems are designed taking into account emergency scenarios: zoning, backup exhaust circuits, control sensors.
- Documentary confirmation of compliance— all technical documentation is drawn up in accordance with the regulatory requirements of Kazakhstan.
- Qualified specialists at every stage— from design to commissioning, with quality control of installation work.
Violation of standards in a chemical laboratory is not an administrative risk, but a direct threat to the health of employees. The accumulation of toxic aerosols and suspended particles, exceeding the permissible level of concentration of harmful substances, the absence of an emergency exhaust circuit – each of these factors can lead to an incident. That is why ABL Engineering Group builds systems with a performance reserve and incorporates backup solutions already at the design stage.
Over the years of operation and more than 40+ specialized facilities, the company has developed clear procedures for monitoring compliance with regulatory documents – from the initial audit of the premises to the final inspection of the installed system before delivery of the facility.
Problems and tasks of ventilation of chemical laboratories
A chemical laboratory is an environment where, during technological processes, experiments and chemical reactions, chemicals are constantly formed.vapors and gases of toxic, hazardous substances. Removing contaminants from the work area is not a matter of convenience, but a condition for the safe operation of the facility. Without a properly designed ventilation system, the concentration of harmful substances in the air quickly reaches maximum permissible values, creating a direct threat to personnel and equipment.
The key task of ventilation in chemical laboratories— continuous removal of harmful substances, vapors and gases from the working area, maintaining a normal microclimate and preventing the spread of hazardous contaminants outside the laboratory premises.
When designing ventilation systems for chemical laboratories, ABL Engineering Group engineers work with a full range of tasks typical for production and research facilities:
- Removal of vapors and gases of toxic substances— localization of contaminants directly at the point of their formation: near fume hoods, reactors, reagent bottling areas. This eliminates the spread of hazardous compounds in adjacent rooms.
- Microclimate monitoring— maintaining standardized values of temperature and air humidity in accordance with the requirements of SanPiN and SNiP. Deviations from the norms affect both the accuracy of experiments and the working conditions of personnel.
- Preventing the spread of pollution— creation of directed air flows and low-pressure zones that prevent the migration of harmful substances into corridors, neighboring laboratories and administrative areas.
- Smoke removal in emergency situations— integration of emergency hood, providing evacuation of combustion products and toxic emissions in emergency situations during production processes.
- Neutralization and air purification— the use of filters and scrubbers to capture chemically active aerosols, acidic vapors and fine particles before being released into the atmosphere.
The complexity of the task is determined by the specifics of the technological processes and reactions occurring in the laboratory. Ventilation of a facility where acids are handled differs from systems designed for organic solvents or alkalis. That is why the calculation of system parameters always precedes the selection of equipment.
| Task | Technical solution | Regulatory framework |
|---|---|---|
| Removal of harmful substances and vapors | Local exhaust ventilation, forced draft fume hoods | SanPiN 2.2.4.548-96, GOST 12.1.005 |
| Temperature and Humidity Control | Air handling units with recovery, automatic control | SNiP 41-01-2003 |
| Preventing the spread of gases | Creating a vacuum in laboratory areas, sluicing | SN RK 4.02-105-2014.2020 |
| Smoke removal | Emergency hood with gas sensors | SN RK 2.02-01.2013 |
| Emission Cleanup | Acid-resistant filters, wet scrubbers | MPC according to GOST 12.1.007 |
Compliance with regulatory requirements – SNiP, SanPiN and specialized GOSTs – is not an optional recommendation, but a mandatory condition for putting a facility into operation and passing supervisory inspections. ABL Engineering Group specialists design systems taking into account current editions of regulatory documents, which eliminates comments from regulatory authorities.
The company’s experience at more than 40+ completed facilities shows that most problems with ventilation in chemical laboratories arise not due to equipment failure, but due to errors at the stage of calculating the air exchange rate and incorrect determination of localization points of hazardous contaminants. That is why ABL Engineering Group begins each project with a detailed technological audit of the premises and analysis of the composition of substances used in production processes and experiments.
Prices, tariffs and commercial offers for ventilation of chemical laboratories
The cost of ventilation for chemical laboratories is determined individually: the total amount depends on the area of the facility, the hazard class of the working environment, the composition of the equipment, the volume of installation work and the requirements for automation. ABL Engineering Group adheres to a transparent pricing policy – every cost item is fixed in the commercial proposal without hidden fees.
We provide a comprehensive solution: design, supply of equipment of our own production, installation by 25 certified teams and regular maintenance of the system during operation. Ordering all stages from one contractor means eliminating inconsistency between the designer, supplier and installation organization.
What is included in the commercial offer
- Technical calculation of parameters— air exchange rate, fan performance, air duct cross-section, system pressure.
- Design— development of working documentation in accordance with the requirements of SanPiN and SNiP, coordination with supervisory authorities.
- Equipment supply— fans, air ducts, filters, fume hoods, automation and control elements.
- Installation and commissioning— carried out by our own teams, quality control at every stage.
- Regular Maintenance— maintaining system functionality, scheduled checks, operational repairs.
- Technical documentation— executive diagrams, equipment passports, acceptance certificates.
Indicative terms of cooperation
| Service stage | Conditions for calculating the cost | CP preparation period |
|---|---|---|
| Ventilation design | Based on the area of the facility, hazard class, composition of premises | 1–3 working days after receiving technical specifications |
| Equipment supply | According to the project specifications, taking into account our own production | Included in the general CP |
| System installation | By volume of work and distance of the object | Together with the project |
| Regular Maintenance | Subscription agreement, conditions – individually | Discussed at the conclusion of the contract |
Regions of work and customer organizations
ABL Engineering Group works with industrial facilities of any scale throughout Kazakhstan. Regions served include:Almaty, Astana, Shymkent, Aktobe and other cities of the country. The company is focused exclusively on the B2B segment: chemical laboratories of scientific institutes, manufacturing enterprises, control and analytical centers and industrial organizations.
Guarantees of quality and reliability of ventilation systems in chemical laboratories
The choice of contractor is a key decision when equipping a facility with industrial ventilation. ABL Engineering Group confirms its reliability not with declarations, but with measurable indicators:work since 2009, 40+ specialized objects throughout Kazakhstan – from Almaty and Astana to Temirtau, Shymkent and Aktobe. Over the years, we have accumulated deep experience in working with chemical laboratories, production buildings and technological complexes of any scale.
The basis of quality assurance isown production ventilation equipment. They work at the Temirtau plant2 production workshops with a total area of over 1000 m² and20 units of CNC machines. This allows you to control every stage of manufacturing air ducts, housing elements and system components – without dependence on third-party manufacturers and intermediary markups. Products are tested for compliance with technical regulations before shipment to the site.
- Qualified specialists and installation teams. The ABL Engineering Group staff includes:own installation teams who have been trained to work with chemically aggressive environments. Production and supply management is carried out by Aleksey Aleksandrovich Korzhuk, the technical department is headed by Lyubov Ivanovna Korzhuk (Head of the Technical Department), project documentation is carried out by Technical Department engineer Semenok Alexander Aleksandrovich.
- Experience working with large industrial clients. Among the implemented objects are projectsArcelorMittal, large factory complexes, shopping centers and office centers. The trust of such customers is an objective confirmation of the level of competence.
- Warranty for equipment and installation work. The terms of the warranty obligations are fixed in the contract. After completion of installation work, the company provides service and maintenance during the operation of the system.
- Repair and prompt response. If malfunctions occur during operation, mobile teams eliminate the problems within the agreed time frame. Repairs are carried out using our own production facilities – without the involvement of subcontractors.
Important: ABL Engineering Group operates exclusively in the B2B segment – industrial facilities, laboratories, production and warehouse complexes. The minimum area of the facility is 500 m². Private orders are not accepted.
A combination of factors – in-house production with modern CNC machines, experienced installation teams, proven design methodology and documented guarantees – forms a systematic approach in which quality does not depend on random variables. Each object is accepted with the signing of work completion certificates and the transfer of as-built documentation to the customer.
| Parameter | ABL Engineering Group indicator |
|---|---|
| Market experience | since 2009 |
| Realized objects | 40+ |
| Installation crews | own |
| Area of production workshops | over 1000 m² |
| CNC machines in production | 20 units |
| Service during operation | Yes, on our own |
| Repair and warranty service | Included in the contract |
If you are interested in reviews from existing customers or detailed warranty conditions, please contact the sales and projects department. The head of the department, Khasanov Ildar Ildarovich, will provide up-to-date information and prepare a commercial proposal for your facility.
Technical parameters and characteristics of ventilation systems for chemical laboratories
Designing ventilation for chemical laboratories requires precise engineering calculations: each system parameter is determined based on the hazard class of the substances, the volume of the room, the nature of the technological processes and the requirements of regulatory documents. Technical Department engineers of ABL Engineering Group – in particular, Semenok Alexander Aleksandrovich and Head of the Technical Department Korzhuk Lyubov Ivanovna – perform a full technical analysis of the facility before the start of design.
Key technical characteristics that are calculated individually for each object:
- Air exchange rate— the minimum indicator for chemical laboratories is 6–10 times per hour, depending on the hazard class of the reagents. When working with highly toxic substances, the multiplicity can reach a maximum calculated value of 15–20 times/hour.
- Air handling unit performance— calculated as air flow in m³/hour, taking into account the volume of laboratory space, the number of fume hoods and local suction.
- System pressure— static pressure is selected based on the length of the air ducts, filter resistance and fan characteristics. For chemical facilities, units with increased resistance to aggressive environments are used.
- Airflow speed— in the working area of the fume hood, the air speed must be at least 0.5 m/s, which ensures reliable removal of vapors and gases without turbulent turbulence.
- Temperature and humidity— microclimate parameters are maintained within the ranges regulated by SanPiN: working area temperature 18–22 °C, air humidity — 40–60%. Deviations from the norm are recorded by the automation system.
- Noise level— when selecting equipment, the permissible noise in laboratory premises is taken into account (no more than 60 dBA), which affects the choice of the type of fans and the method of their vibration isolation.
The system is controlled through an automation panel with the integration of automatic sensors for gas contamination, temperature, humidity and pressure. There can be several sensors in the system – their number and location are determined at the design stage. Automation provides continuous monitoring of air quality, switching to emergency mode when maximum permissible concentrations are exceeded, and remote control of all actuators.
Technical methods of air control, used in ABL Engineering Group systems, include: continuous analysis of air composition through multi-gas sensors, cascade control of fan performance based on a signal from concentration sensors, as well as algorithms for automatic transition to maximum power in emergency situations.
Our own production of equipment at the site in Temirtau (2 workshops with an area of more than 1000 m², CNC machine park) allows us to produce air ducts, fan housings and automation elements with characteristics that exactly correspond to the design parameters of the project. This eliminates the discrepancy between design solutions and actually delivered equipment – a typical problem when working with intermediaries.
| Parameter | Minimum | Maximum calculated | Control method |
|---|---|---|---|
| Air exchange rate (fold/hour) | 6 | 20 | Calculation by volume and hazard class |
| Air flow (m³/hour) | Individually | Individually | Process Analysis |
| Speed in working area (m/s) | 0,5 | 1,2 | Flow velocity sensors (anemometers) |
| Temperature (°C) | 18 | 22 | Automatic temperature sensors |
| Humidity (%) | 40 | 60 | Humidity sensors (hygrometers) |
| Noise level (dBA) | — | 60 | Acoustic calculation at the design stage |
All technical solutions are developed taking into account the current standardization technologies: SN RK 4.02-105-2014, SanPiN 2.2.4.548-96, GOST 12.1.005-88. Head of Production and Supply Alexey Aleksandrovich Korzhuk ensures that the materials and equipment used comply with the specifications stated in the project – from incoming inspection to final acceptance of the installed system.
Frequently asked questions about ventilation in chemical laboratories
What regulatory documents regulate the ventilation of chemical laboratories?
The design and installation of ventilation systems for chemical laboratories in Kazakhstan are regulated by a set of regulatory documents. Key ones:SanPiN— establishes maximum permissible concentrations (MPC) of harmful and toxic substances in the air of the working area;SNiP— determines building standards for the installation of supply and exhaust systems; industry standards for safety requirements at facilities with hazardous chemicals. Compliance with these standards is a mandatory condition when commissioning a facility and passing supervisory inspections.
How is the ventilation system of a chemical laboratory designed?
Design begins with an engineering survey of the facility and calculation of parameters: air volume, air exchange rate, rate of supply and removal of air masses, pressure level in the system. ABL Engineering Group specialists – in particular, PTO engineers under the leadership of Lyubov Ivanovna Korzhuk – analyze the composition of technological processes, the nature of chemical reactions and the list of hazardous substances with which the laboratory works. Based on the calculations, technical documentation is generated: air duct diagrams, equipment specifications, automation and filters. The project is coordinated with the requirements of SanPiN and SNiP before the start of installation work.
What safety measures are provided when installing ventilation?
When installing ventilation systems in chemical laboratories, ABL Engineering Group observes the following safety measures:
- Leak control air ducts – eliminates the leakage of toxic gases and vapors into the work area;
- Emergency ventilation installation— provides emergency removal of polluted air in emergency situations;
- Installation of control sensors concentrations of harmful substances and control automation;
- Use of chemically resistant materials in air ducts and equipment housings;
- Checking system settings after installation is completed – performance, air flow speed, noise level.
All of the company’s own installation teams work according to regulations that meet safety requirements at industrial facilities.
Is it possible to order comprehensive ventilation service after installation?
Yes. ABL Engineering Group providescomprehensive service installed systems: regular technical inspections, replacement of filters, checking the condition of air ducts and fans, setting up automation and monitoring the compliance of parameters with standard values. Regular maintenance allows you to maintain ventilation efficiency at the designed level and promptly prevent the risk of leakage of hazardous substances. The terms of the service agreement are discussed individually when placing an order.
What types of equipment are used in chemical laboratory ventilation systems?
The composition of the equipment is determined by the calculation and hazard class of the object. A typical kit includes:
- Fans— supply and exhaust, in chemically resistant design;
- Air ducts— made of stainless steel or polypropylene, resistant to aggressive environments;
- Filters— to clean the air from toxic particles, vapors and gases;
- Fume hoods— localize the zone of release of harmful substances directly at the workplace;
- Automation and sensors— provide control of contaminant concentration, control of air supply speed and emergency shutdown.
Some of the equipment is produced at ABL Engineering Group’s own enterprise in Temirtau (2 workshops, CNC machine park), which ensures quality control at every stage of production.
How does the company guarantee the quality and reliability of the work performed?
Quality is confirmed by several factors:experience since 2009 and more40+ specialized objects— including industrial enterprises working with hazardous substances. In-house production of equipment eliminates dependence on third-party suppliers and allows you to control the characteristics of each unit. Technical Department engineers – Alexander Aleksandrovich Semenok and colleagues – check the system parameters after installation. The company works with B2B clients at facilities of any size, which ensures specialization and deep expertise in the industrial segment. Among the clients –ArcelorMittal and other large industrial customers.
Which regions of Kazakhstan does ABL Engineering Group serve?
ABL Engineering Group carries out design, installation and maintenance of ventilation systems throughout Kazakhstan. The company operates inAlmaty, Astana, Temirtau, Shymkent, Aktobe and other cities of the country. Our own installation teams (25 units) allow us to quickly travel to sites in any region without involving subcontractors.
How quickly can I receive a commercial offer and consultation?
What risks are associated with improper ventilation in chemical laboratories?
Insufficient or incorrectly designed ventilation creates a direct threat to the safety of personnel and the integrity of the facility:
- Risk of leakage of toxic gases and vapors— accumulation of harmful substances above the maximum permissible concentrations causes acute poisoning;
- Emergency situations— when working with flammable or explosive substances, insufficient removal of contaminated air increases the likelihood of fire;
- Violation of regulatory requirements— non-compliance with SanPiN and SNiP entails orders from supervisory authorities and suspension of activities;
- Reduced research efficiency— unstable microclimate, uncontrolled temperature and humidity distort the results of chemical experiments and reactions.
Why is it important to comply with sanitary standards and requirements when designing ventilation?
Compliance with regulatory requirements is not a formality, but an engineering necessity.SanPiN sets maximum permissible concentration levels of hazardous substances based on proven effects on human health.SNiP regulates the technical parameters of systems providing these levels. Design in accordance with regulatory documents ensures that the ventilation system will effectively remove harmful substances, prevent their spread to adjacent rooms and provide a safe microclimate throughout the entire life of the facility. ABL Engineering Group designs all systems strictly in accordance with current regulations in Kazakhstan.